Mitsubishi Electric FREQROL Manuel d'instructions Page 155

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 524
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 154
Parameter Parameter overview
FR-E700 EC 6 - 15
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Related
parameters
: enabled
—: disabled
Offline auto tuning
94
Motor constant (X)
0.1% *
9999
0–100% *
Tuning data (The value measured
by offline auto tuning is automati-
cally set.)
* The range differs according to
the Pr. 71 setting.
6-88
9999
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
96
Auto tuning setting/
status
10
0
Offline auto tuning is not per-
formed
1
For advanced magnetic flux vector
control
Offline auto tuning is performed
without motor running (all motor
constants)
11
For general-purpose magnetic flux
vector control
Offline auto tuning is performed
without motor running (motor
constant (R1) only)
21
Offline auto tuning for V/F control
(automatic restart after instantane-
ous power failure (with frequency
search))
859
Torque current
0.01A *
9999
0–500A *
Tuning data (The value measured
by offline auto tuning is automati-
cally set.)
* The range differs according to
the Pr. 71 setting.
9999
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
89 Refer to Pr. 81
90
94
Refer to Pr. 82 to 84
96 Refer to Pr. 82 to 84
Tab. 6-1: Parameter overview (15)
Vue de la page 154