Parameter Parameter overview
FR-E700 EC 6 - 9
Func-
tion
Parameter
Name
Incre-
ments
Initial
value
Setting
range
Description
Para-
meter
copy
Para-
meter
clear
All
Para-
meter
clear
Refer
to
page
Related
parameters
: enabled
—: disabled
Remote setting function
59
Remote function
selection
10
RH, RM, RL
signal func-
tion
Frequency setting
storage function
✔✔6-65
0
Multi-speed
setting
1
Remote
setting
Yes
2
Remote
setting
No
3
Remote
setting
No (Turning STF/
STR off clears
remote setting
frequency.)
Energy saving control
selection
60
Energy saving
control selection
10
0 Normal operation mode
✔✔6-171
9
Optimum excitation control mode
(OEC)
Automatic acceleration/deceleration
61 Reference current 0.01A 9999
0–500A
Setting value (rated motor current)
is referenced
✔✔
6-77
9999
Rated inverter current is refer-
enced
62
Reference value at
acceleration
1% 9999
0–200% Setting value is a limit value
✔✔
9999 150% is a limit value
63
Reference value at
deceleration
1% 9999
0–200% Setting value is a limit value
✔✔
9999 150% is a limit value
292
Automatic accelera-
tion/deceleration
10
0 Normal mode
✔✔
1 Shortest
acceleration/
deceleration
mode
Without brake
11 With brake
7 Brake sequence mode 1
8 Brake sequence mode 2
293
Acceleration/decelera-
tion separate selection
10
0
Calculates acceleration/decelera-
tion time of both acceleration and
deceleration for the shortest accel-
eration/deceleration mode.
✔✔
1
Calculates only acceleration time
for the shortest acceleration/decel-
eration mode.
2
Calculates only deceleration time
for the shortest acceleration/decel-
eration mode
Tab. 6-1: Parameter overview (9)