E-62
Replacing the Lamp Cartridge
Preparations: Turning the projector upside-down on top of a soft cloth, etc., so that it does not get scratched makes it easier to
replace the lamp cartridge. Turn the projector right-side up after replacing the lamp cartridge.
1
Unplug the power cord.
2
Turn the projector upside-down.
3
Remove the lamp cover.
(1) Turn the lamp covers set screw counterclockwise and
loosen until the screw turns freely. (The screw does
not come off.)
(2) Open the lamp cover a little, then pull it in the direc-
tion of the arrow and remove it.
4
Remove the lamp cartridge.
(1) Turn the lamp cartridges screw counterclockwise and
loosen them until the screw turn freely. (The screw
do not come off.)
(2) Grasp the lamp cartridges handle and pull upward
to remove the lamp cartridge.