VG79A008H02
SPLIT-TYPE AIR CONDITIONERS
Models
MS12/15/17TN
Series
MSH12/15TN
[FLARE CONNECTION TYPE]
1. THE FOLLOWING SHOULD ALWAYS BE
OBSERVED FOR SAFETY
Please report to your supply authority or obtain their consent before connecting
this equipment to the power supply system.
Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR
SAFETY” before installing the air conditioner.
Be sure to observe the cautions specified here as they include important items
related to safety.
The indications and meanings are as follows.
WARNING
Could lead to death, serious injury, etc.
CAUTION
Could lead to serious injury in particular environments when operated incorrectly.
After reading this manual, be sure to keep it together with the OPERATING
INSTRUCTIONS in a handy place on the customer’s site.
WARNING
Do not install the unit by yourself (customer).
Incomplete installation could cause injury due to fire, electric shock, the unit
falling or leakage of water. Consult the dealer from whom you purchased the
unit or special installer.
Install the unit securely in a place which can bear the weight of the unit.
When installed in an insufficient strong place, the unit could fall causing injury.
Use the indoor/outdoor unit connecting wire that meets the Standards to
connect the indoor and outdoor units and fix the wire to the terminal
block securely so that no external force is conveyed to the connecting
section of the terminal block.
Incomplete connection or fixing of the wire could result in a fire.
Do not use intermediate connection of the power cord or the extension
cord and do not connect many devices to one AC outlet.
It could cause a fire or an electric shock due to defective contact, defective
insulation, exceeding the permissible current, etc.
Check that the refrigerant gas do not leak after installation has com-
pleted.
Perform the installation securely referring to the installation manual.
Incomplete installation could cause a personal injury due to fire, electric
shock, the unit falling or leakage of water.
Perform electrical work according to the installation manual and be sure
to use an exclusive circuit.
If the capacity of the power circuit is insufficient or there is incomplete
electrical work, it could result in a fire or an electric shock.
Attach the electrical cover to the indoor unit and the service panel to the
outdoor unit securely.
If the electrical cover in the indoor unit and/or the service panel in the outdoor
unit are not attached securely, it could result in a fire or an electric shock due
to dust, water, etc.
Be sure to use the part provided or specified parts for the installation
work.
The use of defective parts could cause an injury due to a fire, an electric
shock, the unit falling, leakage of water, etc.
Be sure to cut off the main power in case of setting up the indoor
electronic control P.C. board or wiring works.
It could cause an electric shock.
CAUTION
Ground the unit.
Do not connect the ground to a gas pipe, water pipe, lightning rod or
telephone ground. Defective grounding could cause an electric shock.
Do not install the unit in a place where an inflammable gas leaks.
If gas leak and accumulate in the area surrounding the unit, it could cause an
explosion.
Install a ground leakage breaker depending on the installation place
(Where it is humid).
If a ground leakage breaker is not installed, it could cause an electric shock.
Perform the drainage/piping work securely according to the installation
manual.
If there is a defect in the drainage/piping work, water could drop from the unit
and household goods could be wet and damaged.
2. SELECTING THE INSTALLATION LOCATION
2-1 INDOOR UNIT
Where airflow is not blocked.
Where cool air spreads over the entire room.
Maximum refrigerant piping length between indoor unit and outdoor unit is 49 ft.
and the difference of height of both units is 25 ft. maximum.
Rigid wall without vibration.
Where it is not exposed to direct sunshine.
Where easily drained.
At a distance 3 ft. or more away from your TV and radio (to prevent picture from
being distorted or noise from being generated).
In a place as far away as possible from fluorescent and incandescent lights (so
the infrared remote control can operate the air conditioner normally).
Where the air filter can be removed and replaced easily.
2-2 OUTDOOR UNIT
Where it is not exposed to strong wind.
Where airflow is good and dustless.
Where it is not exposed to rain and direct sunshine.
Where neighbours are not annoyed by operation sound or hot air.
Where rigid wall or support is available to prevent the increase of operation sound
or vibration.
Where there is no risk of combustible gas leakage.
When installing the unit at a high level, be sure to fix the unit legs.
Where it is at least 10 ft. away from the antenna of TV set or radio. (Otherwise,
images would be disturbed or noise would be generated.)
Install the unit horizontally.
CAUTION
Avoid the following places for installation where air conditioner trouble is liable to
occur.
Where there is too much machine oil.
Salty environment as seaside areas.
Hot-spring areas.
Where sulfide gas exists.
Other special atmospheric areas.
2-3 WIRELESS REMOTE CONTROLLER MOUNTING
Place of mounting
Where it is easy to operate and easily visible.
Where children can not touch.
Mounting
Select a position about 4 ft. above the floor, check that signals from the remote
controller are surely received by the indoor unit from that position (‘beep’ or ‘beep-
beep’ receiving tone sounds). After that, attach remote controller mounting
hardware 3 to a pillar or wall and set the wireless remote controller 6.
In rooms where inverter type fluorescent lamps are used, the signal from the
wireless remote controller may not be received.
ADVANCED AND EVER ADVANCING
INSTALLATION MANUAL
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - MSH12/15TN

VG79A008H02SPLIT-TYPE AIR CONDITIONERSModelsMS12/15/17TNSeriesMSH12/15TN[FLARE CONNECTION TYPE]1. THE FOLLOWING SHOULD ALWAYS BEOBSERVED FOR SAFETY•Pl

Page 2 - FLARED CONNECTIONS

IA33-7/1611-7/1612-7/3219-11/163/4 3/43/830-3/410-1/1611-7/3219-11/16IA12CDHEBGF7346PIPING PREPARATION1 Table below shows the specifications of pipes

Page 3 - 4. INDOOR UNIT INSTALLATION

4. INDOOR UNIT INSTALLATION4-1 FIXING OF INSTALLATION PLATE•Find a structural material (such as a stud) in the wall and fix installation platehorizont

Page 4 - 6-1 FLARING WORK

13NL113NL1NL1 L212NL112NL1NL1 L290°5. OUTDOOR UNIT INSTALLATION5-1 POWER SUPPLY AND INDOOR AND OUTDOORWIRE CONNECTION•Connect the indoor/outdoor unit

Page 5 - 4-5 PIPE FORMING

13NL113NL1NL1 L212NL112NL1NL1 L25/8 in. WARNING•Use the indoor/outdoor unit connecting wire that meets the Standards to connectthe indoor and outdoor

Page 6 - 6-2 PIPE CONNECTION

AFlare nutCopper pipeFlaring toolDieCopper pipeFlare nutDieCopper pipeYo r kSmooth all aroundEven lengthall aroundInside is shining without any scratc

Page 7 - 4-6 DRAIN PIPING

Drain hoseDrain capDrain capDrain hoseDownwardslopeWaterleakageDo not raise.WaterleakageAccumulateddrain waterWavingWaterleakageTip of drainhose dippe

Page 8

EMERGENCYOPERATION switchModeOperation Indicator lamp1COOL(Light) (Off)2HEAT(Off) (Light)3STOP(Off) (Off)IndoorunitUnionLiquid pipeGas pipeStop valveO