─ 7 ─
5. Specifications
Model
Rated
voltage
(V)
Rated
frequency
(Hz)
Heater
Motor
speed
Rated
current
(A)
Power con-
sumption
(W)
Air
speed
(m/s)
Noise
(dB)
Weight
(kg)
Drain tank
capacity
(ℓ)
JT-SB216JSH-W-E
JT-SB216JSH-H-E
JT-SB216JSH-S-E
220-240
Single phase
50-60
ON
High 5.7-6.2 1240 106 61
11 0.8
Standard
4.9-5.3 1070 98 58
OFF
High 3.9-4.2 720 106 61
Standard
3.0-3.2 550 98 58
JT-SB216KSN-W-E ――3.0-3.2 550 98 58
• Air speed is calculated from the static pressure measured by the pitot tube (at the nozzle).
• Noise is the A range value measured in an anechoic room.
(Average as three points, 2 m from the front and both sides.)
• The heater is turned off automatically when ambient temperature is 30°C or more. (Applicable models: JT-
SB216JSH-W/H/S-E)
6. Outside dimensions
JT-SB216JSH-W-E, JT-SB216JSH-H-E, JT-SB216JSH-S-E, JT-SB216KSN-W-E
Unit: mm
Commentaires sur ces manuels