Vue de la page 16
FeaturesOptions
Standard
Specifications
Parameter
List
Protective
Functions
Terminal Connection
Diagram
Terminal Specification
Explanation
Outline
Dimension
Drawings
Instructions
FR-D700 Series
Specification
Difference List
Warranty
International
FA Center
Operation panel
Parameter unit
18
Second functions
44 Second acceleration/deceleration time 0 to 3600s 0.1s 5/10/15s ∗2
45 Second deceleration time 0 to 3600s, 9999 0.1s 9999
46 Second torque boost 0 to 30%, 9999 0.1% 9999
47 Second V/F (base frequency) 0 to 400Hz, 9999 0.01Hz 9999
48
Second stall prevention operation
current
0 to 200%, 9999 0.1% 9999
51 Second electronic thermal O/L relay 0 to 500A, 9999 0.01A 9999
Monitor functions
52 DU/PU main display data selection
0, 5, 8 to 12, 14, 20,
23 to 25, 52 to 55, 61,
62, 64, 100
10
54 FM terminal function selection
1 to 3, 5, 8 to 12, 14, 21,
24, 52, 53, 61, 62
1 1
55 Frequency monitoring reference 0 to 400Hz 0.01Hz 60Hz
56 Current monitoring reference 0 to 500A 0.01A
Rated
inverter
current
Automatic
restart
functions
57 Restart coasting time 0, 0.1 to 5s, 9999 0.1s 9999
58 Restart cushion time 0 to 60s 0.1s 1s
59 Remote function selection 0, 1, 2, 3 1 0
60 Energy saving control selection 0, 9 1 0
65 Retry selection 0 to 5 1 0
66
Stall prevention operation reduction
starting frequency
0 to 400Hz 0.01Hz 60Hz
Retry
67 Number of retries at fault occurrence 0 to 10, 101 to 110 1 0
68 Retry waiting time 0.1 to 600s 0.1s 1s
69 Retry count display erase 0 1 0
70 Special regenerative brake duty 0 to 30% 0.1% 0%
71 Applied motor
0, 1, 3, 13, 23, 40, 43,
50, 53
10
72 PWM frequency selection 0 to 15 1 1
73 Analog input selection 0, 1, 10, 11 1 1
74 Input filter time constant 0 to 8 1 1
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17 1 14
77 Parameter write selection 0, 1, 2 1 0
78 Reverse rotation prevention selection 0, 1, 2 1 0
79 Operation mode selection 0, 1, 2, 3, 4, 6, 7 1 0
Motor constants
80 Motor capacity 0.1 to 15kW, 9999 0.01kW 9999
82 Motor excitation current 0 to 500A, 9999 0.01A 9999
83 Rated motor voltage 0 to 1000V 0.1V
200V/400V
∗4
84 Rated motor frequency 10 to 120Hz 0.01Hz 60Hz
90 Motor constant (R1) 0 to 50Ω , 9999 0.001Ω 9999
96 Auto tuning setting/status 0, 11, 21 1 0
PU connector communication
117 PU communication station number 0 to 31 (0 to 247) 1 0
118 PU communication speed 48, 96, 192, 384 1 192
119 PU communication stop bit length 0, 1, 10, 11 1 1
120 PU communication parity check 0, 1, 2 1 2
121 Number of PU communication retries 0 to 10, 9999 1 1
122 PU communication check time interval 0, 0.1 to 999.8s, 9999 0.1s 0
123 PU communication waiting time setting 0 to 150ms, 9999 1 9999
124 PU communication CR/LF selection 0, 1, 2 1 1
125
Terminal 2 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz
126
Terminal 4 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Customer