Explanations of Parameter unit
y The parameter unit is a convenient tool for inverter setting
such as direct input method with a numeric keypad,
operation status indication, and help function.
y Eight languages can be displayed.
y Parameter setting values of maximum of three inverters can
be stored.
The parameter unit connection cable FR-CB20 is required for connecting to
the inverter.
z Main functions
Available function differs by the inverter. Please refer to the instruction manual of the inverter and the parameter unit.
Parameter unit (FR-PU07)
POWER lamp
Lit when the power turns on.
Monitor
Liquid crystal display
(16 characters 4 lines with backlight)
Interactive parameter setting
Trouble shooting guidance
Monitor (frequency, current, power, etc.)
ALARM lamp
Lit to indicate an inverter alarm
occurrence.
FR-PU07
Operation keys
(Refer to the table on the right)
Key Description
Use for parameter setting
Press to choose the parameter setting mode.
First priority monitor is displayed.
In the initial setting, the output frequency is displayed.
Operation cancel key
Used to display the function menu.
A variety of functions can be used on the function menu.
Used to shift to the next item in the setting or monitoring mode.
to
Used to enter a frequency, parameter number or set value.
Inverter operates in the External operation mode.
Used to select the PU operation mode to display the frequency
setting screen.
y Used to keep on increasing or decreasing the running
frequency. Hold down to vary the frequency.
y Press either of these keys on the parameter setting mode
screen to change the parameter setting value sequentially.
y
On the selecting screen, these keys are used to move the cursor.
Forward rotation command key.
Reverse rotation command key.
y Stop command key.
y Used to reset the inverter when an alarm occurs.
y Used to write a set value in the setting mode.
y Used as a clear key in the all parameter clear or alarm history
clear mode.
y Used as a decimal point when entering numerical value.
y The monitor screen selected by the cursor appears.
Function Description
Monitor 6 types of monitors appear by simply pressing .
Frequency setting
For PU operation mode and External/PU combined operation mode (Pr.79 = "3"), frequency setting is available.
Settings is performed by the direct setting, which sets frequency directly by to , and the step setting, which
sets frequency continuously by .
Parameter Setting
Reading parameter and changing setting values are easily done. To change the setting value of an parameter, specify
the parameter number, or select a parameter from the functional parameter list.
Batch copy
FR-PU07 reads parameter settings of an inverter, and stores three different parameter settings.
FR-PU07 can also copy the stored parameter setting to another inverter of the same series, or verify its stored
parameter setting against the parameter setting stored in an inverter.
Operation
Switching between External operation mode [EXT] and PU operation mode [PU] is easy.
Start/stop is enabled during PU operation mode and External/PU operation mode (Pr.79 = "3").