VECTOR INVERTER-INSTRUCTION MANUAL-IB(NA)-0600110E-A (0203) MEEVECTOR INVERTERPrinted in Japan Specifications subject to change without notice.HEAD OF
4INSTALLATIONCAUTION1. Only one type of option per inverter may be used. When two or more options are mounted, pri-ority is in order of slots 1, 2 and
5INSTALLATION2.3 WiringWiring method1) For wiring the control circuit, use cables after stripping their sheaths.Strip the sheaths to the following dim
6INSTALLATION2) Loosen the terminal screw and insert the cable into the terminal.Screw size: M2Tightening torque: 0.22N·m to 0.25N·m Cable size: 0.3mm
7INSTALLATIONRoute the wires so that they do not take up a lot of space in the control circuit terminal block of the option unit.During wiring, do not
83.16-BIT DIGITAL INPUT3.1 Wiring Examples*1 Use the terminal PC on the inverter.*2 AY41 type unit requires 24VDC power.A wiring example of Mitsubishi
916-BIT DIGITAL INPUTREMARKS1. As the input signals are at low level, use two parallel micro signal contacts or a twin contact for relay contact input
1016-BIT DIGITAL INPUT3.2 TerminalsTerminal LocationTerminal Symbol DescriptionOption unitX0 to X15Digital signal input terminals (speed setting signa
1116-BIT DIGITAL INPUT3.3 Code InputThe following lists examples of terminal input state and input value for BCD code and binary code input.In the cas
124.DIGITAL SPEED COMMAND4.1 Digital Speed Command ParameterUse the following parameters to give a speed command using the FR-V5AH. The following para
13DIGITAL SPEED COMMAND4.2 Parameter Setting(1) Input selection (Pr.304 "selection of digital input type and analog compensation input enable / d
A-1Thank you for choosing the Mitsubishi vector inverter option unit.This instruction manual gives handling information and precautions for use of thi
14DIGITAL SPEED COMMAND(2) Data read timing signal on-off selection (Pr.305)! How to use DY signalPr.305 setting Description0The set speed data entere
15DIGITAL SPEED COMMAND(3) Bias adjustment (Pr.300), (Pr.302)Bias adjustments can be made for the digital input signal. Set the set speed at the digit
16DIGITAL SPEED COMMAND! How to set the BCD code or binary value as the output speed settingWhen "9999" is set in Pr.301 (BCD code) or Pr.30
17DIGITAL SPEED COMMAND4.3 Instructions(1) Acceleration/deceleration timeWhen the speed is set with the digital input signal, the acceleration/deceler
185.DIGITAL TORQUE COMMAND5.1 Digital Torque Command ParametersUse the following parameters to give the torque command using the FR-V5AH. The followin
19DIGITAL TORQUE COMMAND(1) Bias adjustment (Pr. 447)Bias adjustments can be made for the digital input signal. Set the torque command value at the di
20DIGITAL TORQUE COMMAND! How to set the digital input value as the torque command valueWhen "9999" is set in Pr. 448, the digital input val
216.ORIENTATION POSITION COMMAND6.1 Orientation Position Command ParameterThe orientation stop position by the 16-bit data input can be given using th
22ORIENTATION POSITION COMMAND[Example 1]4 stop positions [Example 2] 8 stop positions[Example 3] 120 stop positionsPr. 360 = "3" Pr. 360 =
237.SPECIFICATIONS7.1 Specifications!Digital input signal type . . . . . . . . . . . . 4-digit BCD code or 16-bit binary!Digital input signal selectio
A-22. Injury Prevention3. Additional instructionsAlso note the following points to prevent an accidental failure, injury, electric shock, etc.:(1) Tra
REVISIONS*The manual number is given on the bottom left of the back cover.Print Date *Manual Number RevisionMar., 2002 IB(NA)-0600110E-A First edition
A-3(3) Usage(4) Maintenance, inspection and parts replacement(5) Disposal(6) General instruction!Do not modify the equipment.!When parameter clear or
CONTENTS1.PRE-OPERATION INSTRUCTIONS 11.1 Unpacking and Product Confirmation ...
5.DIGITAL TORQUE COMMAND 185.1 Digital Torque Command Parameters ...
11.PRE-OPERATION INSTRUCTIONS1.1 Unpacking and Product ConfirmationTake the option unit out of the package, check the unit name, and confirm that the
2PRE-OPERATION INSTRUCTIONS1.3 StructureFR-V5AHSDSDSDX0X1X2X3X4X5X6X7X8X9X10X11X12X13X14DYX15ConnectorMounting holeTerminal Terminal symbolFront viewM
32.INSTALLATION2.1 Pre-Installation InstructionsMake sure that the input power of the inverter is off.2.2 Installation Procedure(1) Securely insert th