Mitsubishi Electric Air Conditioner Network System
PI controller
PAC-YG60MCA
Installation/Instruction Manual
Before using the PI controller, please read this installation/instruction manual carefully to ensure proper operation.
Keep this installation/instruction manual for future reference.
Contents
Page
1. Safety Precautions.............................................. 1
2. Device Capabilities ............................................. 1
3. Confirmation of Parts .......................................... 2
4. Specifications...................................................... 2
4-1. Product Specifications ....................... 2
4-2. External View ..................................... 2
5. Example of System Configuration....................... 3
6. Installation Method.............................................. 4
6-1. Parts to be Procured Locally.............. 4
6-2. Installation Procedure ........................ 5
7. Wiring Method..................................................... 6
7-1. Names of Parts .................................. 6
7-2. Connecting the Power Line and
M-NET Transmission Line ................. 7
7-3. Connecting the Signal Lines .............. 8
(1) Pulse input (non-voltage a contact) ... 8
8. Initial Setting Procedure...................................... 9
9. Switch List......................................................... 10
10. Display Content................................................. 11
10-1. Display Content List ......................... 11
10-2. Communication Error Status
Display ............................................. 11
11. Test Run ........................................................... 12
12. Precautions for Expansion ................................ 12
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - PI controller

Mitsubishi Electric Air Conditioner Network SystemPI controllerPAC-YG60MCAInstallation/Instruction ManualBefore using the PI controller, please read t

Page 2

9After completing the procedures described in "6 Installation Method" and "7 Wiring Method", set the initial settings in accordanc

Page 3 - 3 Confirmation of Parts

10Set the dip switches for function selection according to the system to be used. At the time of shipment, all dip switches are set to OFF and the M-N

Page 4

11The LEDs of this device indicate the pulse input status and error status of this device.10-1.Display Content List*1: If a communication error occurs

Page 5 - 6 Installation Method

12Use the following procedure to confirm operation of the system.(1) Configure the settings of this device and the system controllers while referring

Page 8 - S / B / A

WT04973X01This product is designed and intended for use in the residential,commercial and light-industrial environment.This product at hand is based o

Page 9

1• Before using the device, thoroughly read the following safety precautions and use as directed.• Hazards and levels of danger that can occur due to

Page 10 - 8 Initial Setting Procedure

2• Confirm that the box contains the following parts.* In addition to the parts mentioned above, other parts need to be procured locally in order to o

Page 11 - 9 Switch List

35 Example of System ConfigurationNote:• For the shield ground of the M-NET centralized control line for central control, use single-point grounding a

Page 12

46-1. Parts to be Procured LocallyPrepare the following parts to install this device.[Parts to be Purchased Separately][Recommended Pulse Specificatio

Page 13 - 12 Precautions for Expansion

56-2. Installation ProcedureThe PI controller PAC-YG60MCA does not have a waterproof structure.Be sure to install the PI controller inside a control p

Page 14

6(3) Refer to "7 Wiring Method" and connect the wires for the power line, M-NET transmission line, and input/output signal lines.7-1. Names

Page 15

77-2. Connecting the Power Line and M-NET Transmission LineCN16 V+/V-/FG CN17 A/B/S S FG M-NETS / B / A (M1) (M2)UURTightening torque for terminal sc

Page 16 - WT04973X01

87-3. Connecting the Signal Lines• Separately procure items such as terminal blocks and cables locally.• The maximum wire length is 100 m. However, si