MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ
4. ELECTRICAL WIRING DIAGRAMS
1 2 3 4 5 6 7 8
Example
When the compressor and
SV1 are turned during cooling
operation.
MODELS
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
SW4
1 MODEL SELECTION
The black square indicates a switch position.
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
SW2 SW8
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
5 6
ON
OFF
5 6
ON
OFF
5 6
Check code
Trouble
Check code
Trouble
Check code
Trouble
1102
Compressor temperature trouble
0403
Serial transmission trouble
Low Pressure sensor trouble (63LS)
1302
High pressure trouble
1500
Excessive refrigerant replenishment
1501
Insufficient refrigerant trouble
1508
Four-way valve disconnection trouble
Blocked valve in cooling mode
2502
Drain pump trouble
2503
Drain sensor trouble (THd)
4100
Overcurrent trouble (Overload, compressor lock)
4116
Fan controller trouble (Indoor unit)
4220
Inverter trouble
4210
Compressor overcurrent trouble
4230
Overheat protection of heat sink
4250
Power module trouble or Overcurrent trouble
4400
Fan controller trouble (Outdoor)
5101
Air inlet sensor trouble (TH21) or
Compressor temperature sensor trouble (TH4)
6603
Transmission error (Transmission route BUSY)
6606
Transmission and reception error (Communication
trouble with transmission processor)
5201
High Pressure sensor trouble (63HS)
5202
5300
Current sensor trouble
6600
Dupricated unit address setting
6602
Transmission error
(Transmission processor hardware error)
5110
IGBT heat sink temperature sensor trouble
(TH8)
7100
Total capacity error
7101
Capacity code error
7102
Connecting unit number error
Combination error
7105
Address set error
7111
Remote controller sensor trouble
7130
6608
Transmission and reception error
(No responsive frame error)
5102
Liquid pipe temp.sensor trouble (TH22) or
Suction pipe temperature sensor trouble (TH6)
5103
Gas pipe temperature sensor trouble (TH23)
5105
Piping temperature sensor trouble (TH3)
5106
Ambient temperature sensor trouble (TH7)
5109
HIC piping temperature sensor trouble (TH2)
6607
Transmission and reception error (No ACK error)
Bit
Indication
1
Compressor
operated
2
52C
3
21S4
4
SV1
5
SV2
6
7
8
Always lit
During normal operation
The LED indicates the drive state of the controller in the outdoor unit.
When fault requiring inspection has occurred
 The LED alternately indicates the inspection code and the location of the unit in which
the fault has occurred.
NOTES:
1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit.
2.Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch
(SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
SYMBOL NAME SYMBOL NAME SYMBOL NAME
TB1 Terminal Block Power Supply
TB1B Terminal Block Branch Box
TB3 Terminal Block
Branch box/Outdoor Transmission Line
Terminal Block
Centralized Control Transmission Line
TB7
FUSE1,FUSE2
Fuse
T20AL250V
MC Motor For Compressor
MF1,MF2 Fan Motor
21S4 Solenoid ValveFour-Way Valve
SV1
Solenoid ValveBypass Valve
SV2
Solenoid ValveSwitching Valve
BH Base heater
TH3
ThermistorOutdoor Liquid Pipe
TH2
ThermistorHic Pipe
TH4
ThermistorCompressor
TH6
ThermistorSuction Pipe
TH7 ThermistorAmbient
63H High Pressure Switch
63HS High Pressure Sensor
63LS Low Pressure Sensor
DCL
P.B. Power Circuit Board
Connection TerminalGround
Connection TerminalU/V/W-Phase
U/V/W
MULTI.B.
FuseT6,3AL250V
F1,F2
SwitchDisplay Selection
SW1
SwitchFunction Selection
SW2
SwitchTest Run
SW3
SwitchModel Selection
SW4
SwitchFunction Selection
SW5
SwitchFunction Selection
SW6
SwitchModel Selection
SW8
SwitchFunction Selection
SW9
SwitchUnit Address Selection, 1st digit
SWU1
SwitchUnit Address Selection, 2nd digit
SWU2
LEDOperation Inspection Display
LED1,LED2
LEDPower Supply to Main Microcomputer
LED3
Controller Circuit Board
ConnectorBase heater
SS
ConnectorConnection For Option
CN3D
Connector
Branch box/Outdoor Transmission Line
CNS1
Connector
Centralized Control Transmission Line
CNS2
ConnectorConnection For Option
CN3S
ConnectorConnection For Option
CN3N
ConnectorConnection For Option
CN51
Relay
X501505
M-NET P.B.
ConnectionTerminalGround
M-NET Power Circuit Board
TB1
Connection TerminalL-Phase
LI
Connection TerminalN-Phase
NI
EI,E2,E3,E4
Power Module
IGBT
Connection TerminalReactor
DCL1,DCL2
Reactor
Use copper supply wires.
Cautions when servicing
Caution for electrical work
!
WARNING: When the main supply is turned off, the voltage [340 V] in the main capacitor will drop to 20 V in approx. 2
minutes (input voltage: 230 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then
wait for at least 1 minute.
Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual.
 Do not replace the outdoor board without checking.
LEV-A,LEV-B
Electronic Expansion Valve
SwitchFunction Selection
SW7
TH8 ThermistorHeat Sink
RED
RED
YLW
YLW
P. B.
BLK
WHT
WHT
WHT
U
U
V
V
W
W
RED
MC
MS
3
M1
M2
S
TB3
TO BRANCH BOX
CONNECTING WIRES
DC 30V(Non-polar)
TO BRANCH BOX
FOR CENTRALIZED
CONTROL
DC 30V(Non-polar)
M1
M2
S
TB7
2
2
GRN/YLW
BLU
RED
POWER SUPPLY
208 / 230V 60Hz
TB1
L1
L2
GR
CN51
WHT
SW6
SW2SW8SW1
SW7SW3SW4
1
1 1
SW5
SWU2 SWU1
SW9
TRANS
LED1
CN2
RED
CN4
WHT
LED3
CN3D
WHT
CN3S
RED
CN3N
BLU
CN1
WHT
B1
BLK
CNDC
PNK
t t t t
MF1
MS
3
LEV-B
M
1 41
3
1
7
3
1 3 1 3 1 3
CN52C
RED
1 3
31
1
2
2 21 11 2
1
2
2
2
1
2
1
2
31
21
TH7 TH6 TH3 TH4
63HS
63H
CNF1
WHT
MF2
MS
3
1
7
1
7
7
1
5
1
5
CNF2
WHT
TH7/6
RED
CNLVB
RED
TH3
WHT
TH4
WHT
t
TH2
t
TH8
TH2
BLK
63HS
WHT
1
3
1
3
63LS
63LS
BLU
63H
YLW
MULTI. B.
LED2
M-NET P.B.
52C
BLK
3
1
3
1
3
1
X505
21S4
GRN
SV1
GRY
SV2
BLU
SS
WHT
21S4
SV1
CNAC
RED
CNS1
RED
CNS2
YLW
F1
F2
X504
X503
X502
X501
CN102
WHT
CN2
WHT
4
4
1
1
CN40
WHT
4
1
5 3
1
CN41
WHT
4
1
BH
SV2
4
2
3
CN2
RED
CN4
WHT
1
2
2
1
7
7
2
2
CNDC
PNK
3 1
2
TB1B
B1
B2
P2
N2
FUSE1
+
-
+
DCL
DCL2 DCL1
IGBT
E I
E 4
E2
CNAC1
WHT
L I
N I
BLK
BLK
21
3
CNAC2
RED
1
3
E3
BLK
2
is the switch position.
LEV-A
M
1
5
CNLVA
WHT
CN52C
RED
1
3
3
52C
52C
BLK
FUSE2