H2i-MXZ-26
M-Series - H2i
®
MXZ Outdoor Units (April 2015)
Due to continuing improvement, above specication may be subject to change without notice.
© 2015 Mitsubishi Electric US, Inc.
MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ
4. ELECTRICAL WIRING DIAGRAMS
1 2 3 4 5 6 7 8
〔Example〕
When the compressor and
SV1 are turned during cooling
operation.
MODELS
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
SW4
※1 MODEL SELECTION
The black square( )indicates a switch position.
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
SW2 SW8
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
5 6
ON
OFF
5 6
ON
OFF
5 6
Check code
Trouble
Check code
Trouble
Check code
Trouble
1102
Compressor temperature trouble
0403
Serial transmission trouble
Low Pressure sensor trouble (63LS)
1302
High pressure trouble
1500
Excessive refrigerant replenishment
1501
Insufficient refrigerant trouble
1508
Four-way valve disconnection trouble
Blocked valve in cooling mode
2502
Drain pump trouble
2503
Drain sensor trouble (THd)
4100
Overcurrent trouble (Overload, compressor lock)
4116
Fan controller trouble (Indoor unit)
4220
Inverter trouble
4210
Compressor overcurrent trouble
4230
Overheat protection of heat sink
4250
Power module trouble or Overcurrent trouble
4400
Fan controller trouble (Outdoor)
5101
Air inlet sensor trouble (TH21) or
Compressor temperature sensor trouble (TH4)
6603
Transmission error (Transmission route BUSY)
6606
Transmission and reception error (Communication
trouble with transmission processor)
5201
High Pressure sensor trouble (63HS)
5202
5300
Current sensor trouble
6600
Dupricated unit address setting
6602
Transmission error
(Transmission processor hardware error)
5110
IGBT heat sink temperature sensor trouble
(TH8)
7100
Total capacity error
7101
Capacity code error
7102
Connecting unit number error
Combination error
7105
Address set error
7111
Remote controller sensor trouble
7130
6608
Transmission and reception error
(No responsive frame error)
5102
Liquid pipe temp.sensor trouble (TH22) or
Suction pipe temperature sensor trouble (TH6)
5103
Gas pipe temperature sensor trouble (TH23)
5105
Piping temperature sensor trouble (TH3)
5106
Ambient temperature sensor trouble (TH7)
5109
HIC piping temperature sensor trouble (TH2)
6607
Transmission and reception error (No ACK error)
Bit
Indication
1
Compressor
operated
2
52C
3
21S4
4
SV1
5
SV2
6
ー
7
ー
8
Always lit
● During normal operation
The LED indicates the drive state of the controller in the outdoor unit.
●
When fault requiring inspection has occurred
The LED alternately indicates the inspection code and the location of the unit in which
the fault has occurred.
NOTES:
1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit.
2.Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch
(SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
SYMBOL NAME SYMBOL NAME SYMBOL NAME
TB1 Terminal Block 〈Power Supply〉
TB1B Terminal Block 〈Branch Box〉
TB3 Terminal Block
〈
Branch box/Outdoor Transmission Line
〉
Terminal Block
〈
Centralized Control Transmission Line
〉
TB7
FUSE1,FUSE2
Fuse 〈
T20AL250V
〉
MC Motor For Compressor
MF1,MF2 Fan Motor
21S4 Solenoid Valve〈Four-Way Valve〉
SV1
Solenoid Valve〈Bypass Valve〉
SV2
Solenoid Valve〈Switching Valve〉
BH Base heater
TH3
Thermistor〈Outdoor Liquid Pipe〉
TH2
Thermistor〈Hic Pipe〉
TH4
Thermistor〈Compressor〉
TH6
Thermistor〈Suction Pipe〉
TH7 Thermistor〈Ambient〉
63H High Pressure Switch
63HS High Pressure Sensor
63LS Low Pressure Sensor
DCL
P.B. Power Circuit Board
Connection Terminal〈Ground〉
Connection Terminal〈U/V/W-Phase〉
U/V/W
MULTI.B.
Fuse〈T6,3AL250V〉
F1,F2
Switch〈Display Selection〉
SW1
Switch〈Function Selection〉
SW2
Switch〈Test Run〉
SW3
Switch〈Model Selection〉
SW4
Switch〈Function Selection〉
SW5
Switch〈Function Selection〉
SW6
Switch〈Model Selection〉
SW8
Switch〈Function Selection〉
SW9
Switch〈Unit Address Selection, 1st digit〉
SWU1
Switch〈Unit Address Selection, 2nd digit〉
SWU2
LED〈Operation Inspection Display〉
LED1,LED2
LED〈Power Supply to Main Microcomputer〉
LED3
Controller Circuit Board
Connector〈Base heater〉
SS
Connector〈Connection For Option〉
CN3D
Connector〈
Branch box/Outdoor Transmission Line
〉
CNS1
Connector〈
Centralized Control Transmission Line
〉
CNS2
Connector〈Connection For Option〉
CN3S
Connector〈Connection For Option〉
CN3N
Connector〈Connection For Option〉
CN51
Relay
X501~505
M-NET P.B.
ConnectionTerminal〈Ground〉
M-NET Power Circuit Board
TB1
Connection Terminal〈L-Phase〉
LI
Connection Terminal〈N-Phase〉
NI
EI,E2,E3,E4
Power Module
IGBT
Connection Terminal〈Reactor〉
DCL1,DCL2
Reactor
• Use copper supply wires.
Cautions when servicing
Caution for electrical work
!
WARNING: When the main supply is turned off, the voltage [340 V] in the main capacitor will drop to 20 V in approx. 2
minutes (input voltage: 230 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then
wait for at least 1 minute.
• Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual.
Do not replace the outdoor board without checking.
LEV-A,LEV-B
Electronic Expansion Valve
Switch〈Function Selection〉
SW7
TH8 Thermistor〈Heat Sink〉
RED
RED
YLW
YLW
P. B.
BLK
WHT
WHT
WHT
U
U
V
V
W
W
RED
MC
MS
3~
M1
M2
S
TB3
TO BRANCH BOX
CONNECTING WIRES
DC 30V(Non-polar)
TO BRANCH BOX
FOR CENTRALIZED
CONTROL
M1
M2
S
TB7
2
2
GRN/YLW
BLU
RED
~208 / 230V 60Hz
TB1
L1
L2
GR
CN51
(WHT)
SW6
SW2SW8SW1
SW7SW3SW4
※1
※1 ※1
SW5
SWU2 SWU1
SW9
TRANS
LED1
CN2
(RED)
CN4
(WHT)
LED3
CN3D
(WHT)
CN3S
(RED)
CN3N
(BLU)
CN1
(WHT)
TB1
BLK
CNDC
(PNK)
t゜ t゜ t゜ t゜
MF1
MS
3~
M
1 41
3
1
7
3
1 3 1 3 1 3
CN52C
(RED)
1 3
31
1
2
2 21 11 2
1
2
2
2
1
2
1
2
31
21
TH7 TH6 TH3 TH4
63HS
CNF1
(WHT)
MF2
MS
3~
1
7
1
7
7
1
5
1
5
CNF2
(WHT)
TH7/6
(RED)
CNLVB
(RED)
TH3
(WHT)
TH4
(WHT)
t゜
TH2
t゜
TH8
TH2
(BLK)
63HS
(WHT)
1
3
1
3
63LS
63LS
(BLU)
63H
(YLW)
MULTI. B.
LED2
M-NET P.B.
52C
(BLK)
3
1
3
1
3
1
X505
21S4
(GRN)
SV1
(GRY)
SV2
(BLU)
SS
(WHT)
21S4
SV1
CNAC
(RED)
CNS1
(RED)
CNS2
(YLW)
F1
F2
X504
X503
X502
X501
CN102
(WHT)
CN2
(WHT)
4
4
1
1
CN40
(WHT)
4
1
5 3
1
CN41
(WHT)
4
1
BH
SV2
4
2
3
CN2
(RED)
CN4
(WHT)
1
2
2
1
7
7
2
2
CNDC
(PNK)
3 1
2
TB1B
B1
B2
P2
N2
FUSE1
+
~
~
-
+
DCL
DCL2 DCL1
IGBT
E I
E 4
E2
CNAC1
(WHT)
L I
N I
BLK
BLK
21
3
CNAC2
(RED)
1
3
E3
BLK
2
is the switch position.
M
1
5
CNLVA
(WHT)
CN52C
(RED)
1
3
3
52C
52C
BLK
FUSE2
Commentaires sur ces manuels