Mitsubishi Electric CMB-P108 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs à système divisé Mitsubishi Electric CMB-P108. BC Controller Engineering Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
BC Controllers (April 2014)
BC-1
© 2014 Mitsubishi Electric US, Inc.
BC CONTROLLER (WITH R2-SERIES, H2i
R2-SERIES AND WR2-SERIES)
CMB-P-NU-G, NU-GA, NU-HA, NU-GB, NU-HB
1. SPECIFICATIONS ........................................................................................................................................................ BC-2
2. EXTERNAL DIMENSIONS ......................................................................................................................................... BC-11
3. ELECTRICAL WIRING DIAGRAMS ........................................................................................................................... BC-16
4. REFRIGERANT CIRCUIT DIAGRAMS AND THERMAL SENSORS .........................................................................BC-26
5. SOUND PRESSURE LEVELS ...................................................................................................................................BC-29
5-1. BC Controller Steady State Sound....................................................................................................................BC-29
5-2. BC Controller Peak Sound ................................................................................................................................BC-30
6. OPTIONAL PARTS ..................................................................................................................................................... BC-31
6-1. BV-Series Ball Valves ........................................................................................................................................BC-31
6-2. BV-Series Ball Valve Insulation .........................................................................................................................BC-31
6-3. CMY-R160C-J Joint Adapter Kit for BC Controllers ..........................................................................................BC-32
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - R2-SERIES AND WR2-SERIES)

BC Controllers (April 2014)BC-1© 2014 Mitsubishi Electric US, Inc.BC CONTROLLER (WITH R2-SERIES, H2i™ R2-SERIES AND WR2-SERIES)CMB-P-NU-G, NU-GA, NU-H

Page 2

BC-10BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.1. SPECIFICATIONS1. SPECIFICATIONSDATA U10INDOOR UNITS 1 - 168BCModel name CMB-P101

Page 3

BC Controllers (April 2014)BC-11© 2014 Mitsubishi Electric US, Inc.CMB-P105,106,108,1010,1013,1016NU-GDrw. : CMB-P-NU-G_W659644Unit : mm(in)(5-1/16)(2

Page 4

BC-12BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.CMB-P108,1010,1013NU-GADrw. : CMB-P-NU-GA_W659642Unit : mm(in)216116(7-7/8)(8-17/32

Page 5

BC Controllers (April 2014)BC-13© 2014 Mitsubishi Electric US, Inc.ø31(Note 2.)200200(700)250Drain hose(Accessory)Band(Accessory) Access door45

Page 6

BC-14BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.2. EXTERNAL DIMENSIONSCMB-P104,108NU-GBDrw. : CMB-P-NU-GB_W659643Unit : mm(in)12811

Page 7

BC Controllers (April 2014)BC-15© 2014 Mitsubishi Electric US, Inc.2. EXTERNAL DIMENSIONS12864 116(Note 2.)XConnection pipe ofindoor unit(Gas)Connecti

Page 8

BC-16BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.(Red)CNTRZNR02ZNR01L2X21CN36(Green)31321321SVM1CN29(Green)X33X7X8135714321141615SV4

Page 9

BC Controllers (April 2014)BC-17© 2014 Mitsubishi Electric US, Inc.CN36(Green)L2L1ZNR02CN29(Green)CN28(Blue)CN27(Red)ZNR01CN05CN07S(SHIELD)M1M2TB02X21

Page 10 - 1. SPECIFICATIONS

BC-18BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc. 2.The initial set values of switch on CONT.B are as follows.

Page 11 - 2. EXTERNAL DIMENSIONS

BC Controllers (April 2014)BC-19© 2014 Mitsubishi Electric US, Inc.ZNR01ZNR02L1L2TB01M1M2TB02S(SHIELD)CN32CN33(Red)CN34(Black)CN35(Blue)CN36(Green)CN3

Page 12 - CMB-P108,1010,1013NU-GA

BC-2BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.1. SPECIFICATIONSI.BC controller (for R2 PURY)1. SPECIFICATIONSModel name CMB-P105NU

Page 13 - CMB-P1016NU-HA

BC-20BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.3. ELECTRICAL WIRING DIAGRAMSNote:1.TB02 is transmission terminal block.

Page 14

BC Controllers (April 2014)BC-21© 2014 Mitsubishi Electric US, Inc.CNTR(Red)CN41(Green)CN40(Yellow)CN34(Black)CN33(Red)CN35(Blue)ZNR01ZNR02CN0654321LE

Page 15

BC-22BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.3. ELECTRICAL WIRING DIAGRAMSTerminalT1~16T16T15T14T13T12T11T10T9 T8 T7T6T5T4T3T2T1

Page 16 - 3. ELECTRICAL WIRING DIAGRAMS

BC Controllers (April 2014)BC-23© 2014 Mitsubishi Electric US, Inc.ZNR02ZNR01CN29(Green)CN28(Blue)CN27(Red)CNTR(Red)CN07L1L2TB01CN13CN03M1M2S(SHIELD)T

Page 17

BC-24BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.CN31(Yellow)CN33(Red)CN34(Black)CN35(Blue)CN30(Black)CN29(Green)CN28(Blue)CN27(Red)

Page 18

BC Controllers (April 2014)BC-25© 2014 Mitsubishi Electric US, Inc.L2L1GGNote:1.TB02 is transmission terminalblock.Never connect power lineto it.2.The

Page 19

BC-26BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.CMB-P104 - P1016NU-G (Single)TH15TH12LEV3LEV1TH16PS3PS1TH11SVM1Gas/LiquidseparatorC

Page 20

BC Controllers (April 2014)BC-27© 2014 Mitsubishi Electric US, Inc.CMB-P108, P1013NU-GA (Main)CMB-P104, P108NU-GB (Sub)TH15TH12LEV3SVM2LEV1LEV2TH16PS3

Page 21

BC-28BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.CMB-P1016NU-HB (Sub)TH15TH12HIC-CCPLEV3Check valve blockSolenoid valve block4. REFR

Page 22

BC Controllers (April 2014)BC-29© 2014 Mitsubishi Electric US, Inc.5. SOUND PRESSURE LEVELS5-1. BC Controller Steady State SoundMeasured in an anechoi

Page 23

BC Controllers (April 2014)BC-3© 2014 Mitsubishi Electric US, Inc.1. SPECIFICATIONS1 - 1611. SPECIFICATIONSDATA U10INDOOR UNITSBCModel name CMB-P106NU

Page 24

BC-30BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.5-2. BC Controller Peak Sound5. SOUND PRESSURE LEVELSMeasured in an anechoic chambe

Page 25

BC Controllers (April 2014)BC-31© 2014 Mitsubishi Electric US, Inc.6. OPTIONAL PARTS6-1. BV-Series Ball Valves6-2. BV-Series Ball Valve Insulation• Fu

Page 26 - CMB-P104 - P1016NU-G (Single)

BC-32BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.6. OPTIONAL PARTSPURY-P-T(S)KMU/Y(S)KMU ; PURY-HP-T(S)KMU/Y(S)KMU ;PQRY-P72~240T/Y(

Page 27 - CMB-P1016NU-HA (main)

BC-4BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.1. SPECIFICATIONSDATA U10INDOOR UNITS 1 - 162BCModel name CMB-P1010NU-G CMB-P1013NU-

Page 28 - CMB-P1016NU-HB (Sub)

BC Controllers (April 2014)BC-5© 2014 Mitsubishi Electric US, Inc.1 - 1631. SPECIFICATIONSDATA U10INDOOR UNITSBCModel name CMB-P1016NU-GNumber of bran

Page 29 - 5. SOUND PRESSURE LEVELS

BC-6BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.1. SPECIFICATIONSDATA U10INDOOR UNITS 1 - 164BCModel name CMB-P108NU-GA CMB-P1010NU-

Page 30 - 5-2. BC Controller Peak Sound

BC Controllers (April 2014)BC-7© 2014 Mitsubishi Electric US, Inc.1 - 1651. SPECIFICATIONSDATA U10INDOOR UNITSBCModel name CMB-P1013NU-GA CMB-P1016NU-

Page 31 - 6-1. BV-Series Ball Valves

BC-8BC Controllers (April 2014)© 2014 Mitsubishi Electric US, Inc.1. SPECIFICATIONSDATA U10INDOOR UNITS 1 - 166BCModel name CMB-P1016NU-HANumber of br

Page 32

BC Controllers (April 2014)BC-9© 2014 Mitsubishi Electric US, Inc.1 - 1671. SPECIFICATIONSDATA U10INDOOR UNITSBCModel name CMB-P104NU-GB CMB-P108NU-GB

Commentaires sur ces manuels