Vue de la page 10
DX-TL800E
TECHNICAL SPECIFICATIONS
Item Description
Main Recording Medium 3.5inch IDE HDD 2 can be added internally
(Maximum capacity:2TB/port)
Colour system Standard PAL system
Signal Compression System Wavelet: Sampling 13.5 MHz
Compression unit: Field
Number of Picture 684 x 288 pixels
Elements Processed
Video terminal Input 4 Input BNC-Connector:1.0V(p-p)75
Output 1 Output BNC-Connector:1.0V(p-p)75
Audio Terminal Input 1 Input RCA-Pin plug:308mV(rms),50k
Output 1 Output RCA-Pin plug:308mV(rms),1k
Horizontal Resolution More than 450 lines (Super and High picture grade)
Recording Interval Can be set for each camera with function to estimate
recording possible time
Alarm Recording Recording time: 2sec, 5sec, 10sec, 15sec, 30sec, 45sec, 1min, 2min, 5min,
10min, 20min, 30min, 60min and contact input
Alarm Partition Recording The partition area can be set from 10%to 90%of HDD capacity
Pre-alarm Recording Pre-alarm time period has 3 settings,long,middle and short
Mirror Recording Prevent data loss due to the HDD crash is available
Emergency Recording Emergency input terminal (rear)
Power Failure Recovery Recording Auto-re-start of unit after power failure
Menu Language English, German, French, Spanish, Italian and Russian
Item Description
Digital Zoom The screen is magnified by 100%,200%,and 400%
Motion Detection Function 16(H) x 12(V) detection area setting,5 steps detection sensitivity setting,
recoding start dot number setting
Retrieval Date & Time search,index search,skip search, alarm list search,
camera filtering search
Multiplexer Function Split display:4 split display
Sequential display:1/4 display
Ethernet 10 BASE-T (RJ-45)
Simultaneous Users Access Monitoring:Max.5 users (Net Hunter lite)
Playback:Max.1 user
Security Password (a three-level password)
Image-alteration recognition (Against image forging)
Remote Access Interface RS-232C (D-SUB 9pins)
Power Supply AC100-240V 50/60Hz
Power Consumption 0.2A (240V,with 2 HDDs)
Operational Conditions Temperature: 5ºC-40ºC
Humidity: 30%-80%
Altitude: Max 2000m
Dimensions (W x D x H) 300 x 343 x 88mm
Weight 5.8kg
Accessories AC power code (UK and Continental plug), Instruction manual (English)
Quick Guide (English, German, French, Spanish, Italian and Russian)
Wired remote control R-400
Screw to attach the HDD to the HDD holder
Item Description
Main Recording Medium 120GB fixed magnetic recording device (HDD)
Possible to maximum 240GB (120GB x 2)
External Recording Medium CompactFlash™ Card slot for copying data
Colour system PAL system
Signal Compression System Wavelet: Sampling 13.5 MHz
Compression unit: Field
Number of Picture Elements 684 x 288 pixels
Processed
Video terminal Input 9-channel input BNC: 1.0Vp-p 75
Output 9-channel through output BNC: 1.0Vp-p 75
(during AC power supply)
Monitor output 2 BNC: 1.0Vp-p 75
S terminal: Y 1.0Vp-p 75/C 0.3Vp-p 75
Audio Terminal Input 3.5ø Microphone-67dBs 600
RCA plug-8dBs 50K
Output RCA plug on front and rear-8dBs 1K
Horizontal Resolution More than 450 lines (Super and High picture grade)
Recording Interval Can be set for each camera with function to estimate
recording possible time
Alarm Recording Recording time: 2sec, 5sec, 10sec, 15sec, 30sec, 45sec, 1min, 2min, 5min,
10min, 20min, 30min, 60min and contact input
Pre-alarm Recording Pre-alarm time period has 3 settings, long, middle and short
Item Description
Emergency Recording Emergency input terminal (rear)
Power Failure Recovery Recording Auto-re-start of unit after power failure
Used Capacity Recording Displays percentage of hard disk space used
Menu Language English, German, French, Spanish and Russian
Motion Detection Function 16(H) x 12(V) detection area setting, 5 steps detection sensitivity setting,
recoding start dot number setting
Timer Adjusting Function Time adjusting input (rear terminal)
Retrieval Date & Time search, index search, skip search, alarm list search,
camera filtering search
Multiplexer Function Split display:4 split display
Sequential display:1/4 display
Remote Access Interface RS-232C (D-SUB 9pins)
Power Supply AC100-240V 50/60Hz
Power Consumption 0.25A (240V)
Operational Conditions Temperature: 5ºC-40ºC
Humidity: 30%-80%
Altitude: Max 2000m
Dimensions (W x D x H) 300 x 350 x 88mm
Weight 7kg
Accessories AC power code (UK and Continental plug)
Instruction manual (English)
Quick Guide (English, German, French, Spanish and Russian)
DX-NT400E
Specifications are subject to change without notice
Vue de la page 10