Mitsubishi Electric EHST20 Series Manuel d'installation Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 51
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
CNP1(WHT)
TBI.1
CNV1
(WHT)
FTC 4
TBO.2
TBO.1
1
3
1
5
1
3
1
5
SW3
1
8
1
6
10
11
12
13
14
10
11
12
13
14
1
5
CN01
(BLK)
1
3
CN3C
(BLU)
CNBH
(WHT)
1
7
CNBC
 (GRY)
1
3
CNBHT
 (BLK)
1
3
CNIH
 (ORN)
1
2
CN22
(BLU)
CN2F
(YLW)
1
3
CN20
(RED)
CN21
(YLW)
1
3
CNW12
(RED)
CNW5
(WHT)
1
2
1
4
1
2
10
11
13
12
14
TBI.2
10
11
13
12
14
LED1
LED2
CNPWM
(WHT)
1
3
SW2
1
8
SW1
1
8
SW4
CN108
CNRF
(WHT)
LED4
LED3
1
5
CN105
(RED)
22
System Set Up
5
GB
5.2 Connecting inputs/outputs
When the wires are wired to adjacent terminals use ring terminals and insu-
late the wires.
<Figure 5.2.1>
Signal inputs
Name Terminal block Connector Item OFF (Open) ON (Short)
IN1 TBI.1 1-2 Room thermostat 1 input Refer to SW2-1 in <5.1 Dip Switch Functions>.
IN2 TBI.1 3-4 CN2F Flow switch 1 input Refer to SW2-2 in <5.1 Dip Switch Functions>.
IN3 TBI.1 5-6 Flow switch 2 input (Zone1) Refer to SW3-2 in <5.1 Dip Switch Functions>.
IN4 TBI.1 7-8 Demand control input
Normal Heat source OFF/ Boiler operation *2
IN5 TBI.1 9-10 Outdoor thermostat input (*1)
Standard operation Heater operation/ Boiler operation *2
IN6 TBI.1 11-12 Room thermostat 2 input Refer to SW3-1 in <5.1 Dip Switch Functions>.
IN7 TBI.1 13-14 Flow switch 3 input (Zone2) Refer to SW3-3 in <5.1 Dip Switch Functions>.
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may be reduced.
*2. To turn on the boiler operation, use the main controller to select “Boiler” in “External input setting“ screen in the service menu.
Item Name Model and specications
Signal input
function
Signal input
wire
Use sheathed vinyl coated cord or cable.
Max. 10 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.5 mm² to 1.25 mm²
Solid wire: ø0.65 mm to ø1.2 mm
Switch Non-voltage “a” contact signals
Remote switch: minimum applicable load 12V DC, 0.1mA
Wiring specication and eld supply parts
Thermistor inputs
Name Terminal block Connector Item Optional part model
TH1 CN20 Thermistor (Room temp.) (Option) *1 PAC-SE41TS-E
TH2 CN21 Thermistor (Ref. liquid temp.)
THW1 CNW12 1-2 Thermistor (Flow water temp.)
THW2 CNW12 3-4 Thermistor (Return water temp.)
THW5 CNW5 Thermistor (DHW tank water temp.)
THW6 TBI.2 7-8 Thermistor (Zone1 ow water temp.) (Option)*1
PAC-TH011-E
THW7 TBI.2 9-10 Thermistor (Zone1 return water temp.) (Option)*1
THW8 TBI.2 1-2 Thermistor (Zone2 ow water temp.) (Option)*1
PAC-TH011-E
THW9 TBI.2 11-12 Thermistor (Zone2 return water temp.) (Option)*1
THWB1 TBI.2 3-4 Thermistor (Boiler ow water temp.) (Option)*1
PAC-TH011HT-E
THWB2 TBI.2 5-6 Thermistor (Boiler return water temp.) (Option)*1
Do not splice the wiring to extend or shorten it, or this could affect correct monitoring of each temperature.
If the wiring is too long, bundle it with a strap to adjust the length.
*1. The maximum length of the thermistor wiring is 5 m.
When the wires are wired to adjacent terminals, use ring terminals and insulate the wires.